These are the standard details for proposed work within City of Jacksonville rights of way or easements. For work within Florida Department of Transportation (FDOT) rights of way, go to the FDOT Design Standards Web site for their standard details.
You will need AutoCAD or a similar product to open DWG files. AutoCAD is available at the Autodesk Company Web site: http://usa.autodesk.com/.
All Details (ZIP 6.6MB)
Roadways
Drainage
Water
Sewer
Traffic
--- ROADWAY STANDARD SECTION ---
Roadway Series 100
ROADWAYS
P-101 (DWG 73KB) - Residential 60' R/W
P-102 (DWG 71KB) - Residential 50' R/W
P-103 (DWG 85KB) - Industrial 60' R/W w/ Swales
P-104 (DWG 80KB) - Industrial 60' R/W w/ C&G
P-105 (DWG 95KB) - Light Industrial or Collector 80' R/W
P-106 (DWG 110KB) - Industrial or Collector 100' R/W w/ Swales
P-107 (DWG 126KB) - Industrial or Collector 100' R/W w/ C&G
P-108 (DWG 65KB) - Arterial 120' R/W
P-109 (DWG 62KB) - Rigid Pavement 60' R/W (Urban)
P-110 (DWG 66KB) - Rigid Pavement Joint Details
P-111 (DWG 55KB) - Standard Cul-De-Sac w/ C&G
P-112 (DWG 55KB) - Standard Cul-De-Sac w/ Swales
P-113 (DWG 37KB) - Special T Turn Around
P-114 (DWG 51KB) - Bicycle Lanes
P-115 (DWG 80KB) - Typical Valley Gutter
Roadway Series 200
PRIVATE D/W AND ROADWAYS
P-201 (DWG 60KB) - Driveway Entrance-Class II & III
P-202 (DWG 88KB) - Inverted Crown
P-203 (DWG 156KB) - Private Drive w/ Parking
P-204 (DWG 74KB) - Asphaltic Concrete Driveway
P-205 (DWG 47KB) - Class I Concrete Driveway
P-206 (DWG 80KB) - Class II Commercial Concrete Driveway
Roadway Series 300
CURB & GUTTER AND HANIDCAP
P-301 (DWG 53KB) - Standard Curb & Gutter Templates
P-302 (DWG 134KB) - Physically Handicapped Ramps
P-303 (DWG 133KB) - Physically Handicapped Ramps
P-304 (DWG 586KB) - Physically Handicapped Ramps
P-305 (DWG 43KB) - Physically Handicapped Ramps
P-306 (DWG 90KB) - Physically Handicapped Parking
Roadway Series 400
PAVEMENT REPAIRS
P-401 (DWG 90KB) - Manhole Adjustment Detail
P-402 (DWG 132KB) - Paving Repair Detail Case I
P-403 (DWG 132KB) - Paving Repair Detail Case II
P-404 (DWG 74KB) - Paving Repair Detail Case III
P-405 (DWG 61KB) - Paving Repair Detail Case IV
P-406 (DWG 47KB) - Paving Repair Detail Case V
P-407 (DWG 55KB) - Paving Repair Detail Case VI, VII, & VIII
P-408 (DWG 113KB) - Paving Repair Detail Case IX
P-409 (DWG 61KB) - Paving Repair Detail Case X
P-410 (DWG 53KB) - Paving Repair Detail Case XI
P-411 (DWG 93KB) - Paving Repair Detail Case XII
P-412 (DWG 53KB) - Paving Repair Detail Case XIII
P-413 (DWG 56KB) - Paving Repair Detail Case XIV
Roadway Series 500
TRADITIONAL NEIGHBORHOOD UTILITY LOCATION
P-501 (DWG 42KB) - TND Boulevard
P-502 (DWG 60KB) - TND Village Center Street
P-503 (DWG 38KB) - TND Local Street #1
P-504 (DWG 38KB) - TND Local Street #2
P-505 (DWG 38KB) - TND Local Street #3
P-506 (DWG 35KB) - TND Alley
Roadway Series Misc.
Utrench (DWG 52KB) - Pavement Replacement Over Utility Trench
top
--- DRAINAGE STANDARD SECTION ---
Drainage Series 100
MANHOLES
D-101 (DWG 75KB) - Storm Sewer Type J-1 Through J-1-F Manhole
D-102 (DWG 60KB) - Storm Sewer Type J-2 Manhole
D-103 (DWG 66KB) - Storm Sewer Type J-3 Manhole
D-104 (DWG 67KB) - Storm Sewer Type J-4 Manhole
D-105 (DWG 59KB) - Storm Sewer Type J-5 Manhole
D-106 (DWG 52KB) - Storm Sewer Brick Manhole
D-107 (DWG 38KB) - Notes For Manholes & Inlets
D-108 (DWG 84KB) - Slab Design-Square & Rectangular Structures
D-109 (DWG 41KB) - Wall Design-Rectangular Structures
D-110 (DWG 43KB) - Slab Design-Round Structures
Drainage Series 200
INLETS
D-201 (DWG 65KB) - Storm Sewer Curb Inlet
D-202 (DWG 56KB) - Standard Curb Inlet Installation
D-203 (DWG 71KB) - Storm Sewer 46" I.D. Inlet
D-204 (DWG 116KB) - Storm Sewer Double & Triple Curb Inlet
D-205 (DWG 136KB) - Storm Sewer Type "B" Inlet
D-206 (DWG 140KB) - Storm Sewer Double Type "B" Inlet
D-207 (DWG 127KB) - Storm Sewer Type "C" Inlet
D-208 (DWG 69KB) - Storm Sewer Type "E" Inlet
D-209 (DWG 55KB) - Detail For Type "C & E" Inlet
D-210 (DWG 43KB) - Eye Bolt & Chain For Locking Grates To Inlets
D-211 (DWG 176KB) - Sand Trap Basin
D-212 (DWG 35KB) - Invert Detail
Drainage Series 300
CASTINGS
D-301 (DWG 67KB) - Storm Sewer Manhole Cover & Frame Storm
D-302 (DWG 45KB) - Sewer Curb Inlet Frame
D-303 (DWG 41KB) - Storm Sewer Curb Iron
D-304 (DWG 44KB) - Storm Sewer Inlet Grate
D-305 (DWG 44KB) - Storm Sewer Catch Basin Frame
D-306 (DWG 47KB) - Curb Iron W/Grate & Frame
D-307 (DWG 79KB) - Grate Detail For Type "E" Inlet
D-308 (DWG 42KB) - Manhole Cover Detail
Drainage Series 400
ENDWALLS
D-401 (DWG 63KB) - Straight Concrete Endwalls-Single & Multiple Pipe
D-402 (DWG 51KB) - Straight Concrete Endwalls-Single & Multiple Pipe
D-403 (DWG 56KB) - Straight Concrete Endwalls-Single & Multiple Pipe
D-404 (DWG 36KB) - Straight Concrete Endwalls-Single & Multiple Pipe
D-405 (DWG 42KB) - Straight Concrete Endwalls-Single & Multiple Pipe
D-406 (DWG 49KB) - Straight Endwall For 60"-78" Concrete Pipe Culverts
D-407 (DWG 40KB) - Dimensional & Quantitative Data For 60"-78" Concrete Pipe Endwalls
D-408 (DWG 68KB) - Concrete Endwall With 45' Wings For Pipe Culverts
D-409 (DWG 58KB) - Concrete Endwall With U-Shaped Wings For Pipe Culverts
D-410 (DWG 61KB) - Flared End Section For Pipe Culverts
D-411 (DWG 87KB) - Sand-Cement Rip Rap Endwall
D-412 (DWG 77KB) - Concrete Endwall For Multiple 60"-78" Round Pipes
D-413 (DWG 46KB) - Dimensional & Quantitative Data For Multiple 60"-78" Concrete Pipe Endwalls
D-414 (DWG 59KB) - Straight Endwall For Single Precast Concrete Box Culverts
D-415 (DWG 65KB) - Straight Endwall For Double Precast Concrete Box Culverts
D-416 (DWG 58KB) - Straight Endwall For Triple Precast Concrete Box Culverts
D-417 (DWG 46KB) - Sections Of Endwall For 4' High Single, Double, & Triple Precast Box Culverts
D-418 (DWG 44KB) - Sections Of Endwall For 5' High Single, Double, & Triple Precast Box Culverts
D-419 (DWG 43KB) - Sections Of Endwall For 6' High Single, Double, & Triple Precast Box Culverts
D-420 (DWG 35KB) - Bar Bending Diagram For Steel In Endwall For Single, Double, & Triple Precast Box Culverts
D-421 (DWG 65KB) - Dimensional & Quantitative Data For Single Box Culvert Endwalls
D-422 (DWG 65KB) - Dimensional & Quantitative Data For Single Box Culvert Endwalls
D-423 (DWG 40KB) - Dimensional & Quantitative Data for Single Box Culvert Endwalls
D-424 (DWG 65KB) - Dimensional & Quantitative Data for Double Box Culvert Endwalls
D-425 (DWG 65KB) - Dimensional & Quantitative Data for Double Box Culvert Endwalls
D-426 (DWG 40KB) - Dimensional & Quantitative Data for Double Box Culvert Endwalls
D-427 (DWG 65KB) - Dimensional & Quantitative Data for Triple Box Culvert Endwalls
D-428 (DWG 50KB) - Concrete Endwall with L-Type Wing for Pipe Culverts
D-429 (DWG 44KB) - Precast Mitered End for Driveway Culverts
D-430 (DWG 46KB) - Precast Mitered End for Elliptical Driveway Culverts
D-431 (DWG 46KB) - Standard Mitered End Section for RCP or CMP
D-432 (DWG 34KB) - Standard Table of Dimensions for Mitered End Section
D-433 (DWG 40KB) - Standard Flared End Sections for Corrugated Metal Pipe
D-434 (DWG 39KB) - Dimensional Data of Flared End Sections for Corrugated Metal Pipe
D-435 (DWG 65KB) - Mitered End Section for RCP or ERCP Cross Drain Type B Section
D-436 (DWG 148KB) - Connector Detail for Mitered End Section
D-437 (DWG 49KB) - Tables of Dimension for Mitered End Sections Type B
Drainage Series 5OO
DITCH PAVING
D-501 (DWG 49KB) - Concrete Ditch Paving & Weep Hole Arrangement
D-502 (DWG 61KB) - Alternate Weephole Detail
Drainage Series 600
CHECK DAM
D-601 (DWG 79KB) - Temporary Sand-Cement Rip Rap Check Dam
D-602 (DWG 39KB) - Concrete Check Dam
Drainage Series 700
UNDERDRAIN
D-701 (DWG 61KB) - Underdrain Installation Type I
D-702 (DWG 60KB) - Underdrain Installation Type II
D-703 (DWG 39KB) - Underdrain Installation Type III
D-704 (DWG 56KB) - Underdrain Cleanout Detail
D-705 (DWG 40KB) - Paved Outfall for Underdrain
D-706 (DWG 75KB) - Prefabricated Edge Drain Detail
Drainage Series 800
PIPE BEDDING
D-801 (DWG 42KB) - Pipe Bedding Case 1
D-802 (DWG 53KB) - Pipe Bedding Case 2
D-803 (DWG 57KB) - Pipe Bedding Case 3
D-804 (DWG 60KB) - Culvert Placement with Less Than 12" Cover
Drainage Series 900
EROSION & SEDIMENT CONTROL
D-901 (DWG 123KB) - Hay Bale Location
D-902 (DWG 547KB) - Block & Gavel Curb Inlet Sediment Filter
D-903 (DWG 147KB) - Gravel Inlet Sediment Trap
D-904 (DWG 176KB) - Block & Grovel Drop Inlet Sediment Filter
D-905 (DWG 172KB) - Drop Inlet Sediment Filter
D-906 (DWG 40KB) - Spacing Recommendation for Silt Fences & Hay Bales
D-907 (DWG 116KB) - Turbidity Barriers
D-908 (DWG 140KB) - Silt Fence Type III & IV
D-909 (DWG 360KB) - Construction Details for Silt Fences
D-910 (DWG 333KB) - Filter Barrier Construction Detail
D-911 (DWG 94KB) - Staked Hay Bale
D-912 (DWG 116KB) - Hay Bale Barriers Type I & II
D-913 (DWG 615KB) - Hay Bale Construction Details
D-914 (DWG 88KB) - Diversion Dike
D-915 (DWG 50KB) - Temporary Seeding Plant Materials
D-916 (DWG 37KB) - Seeding Mixtures Rates & Dates
Drainage Series 1000
STORMWATER PONDS
D-1001 (DWG 39KB) - Detention Pond Detail Case 1
D-1002 (DWG 49KB) - Detention Pond Detail Case 2 & 3
D-1003 (DWG 41KB) - Detention Pond Detail Case 4
D-1004 (DWG 46KB) - Detention Pond Detail Case 5
Drainage Series 1100
POLYETHLENE PIPE
D-1101 (DWG 37KB) - Polyethylene Pipe Trench Detail
top
--- WATER STANDARD SECTION ---
W-1 (DWG 35KB) - Suggested Meter Installations 3" thru 20" Meters
W-2 (DWG 23KB) - Meter Installation - 5/8" thru 2"
W-3 (DWG 37KB) - Meter Box for 5/8", 3/4" &. 1" Meters
W-4 (DWG 32KB) - Meter Box for 1 1/2" & 2" Meters
W-5 (DWG 20KB) - Cast Iron Meter Box Covers
W-6 (DWG 30KB) - Installation Details - 3" thru 20" Meters
W-7 (DWG 54KB) - Precast Meter Box - 3" thru 20" Meters
W-8 (DWG 14KB) - Precast Meter Box Dimensions - 3" thru 20" Meters
W-9 (DWG 20KB) - Precast Meter Box Top
W-10 (DWG 62KB) - Precast Meter Box Dimensions (6'x6', 4'x4')
W-11 (DWG 18KB) - Precast Meter Box Walls (6'x6', 4'x4')
W-12 (DWG 57KB) - Hydrant Installation with Tie Rods Using Tapping Sleeve and Valve
W-13 (DWG 66KB) - Hydrant Installation with Tie Rods Using Mechanical Joint Fittings
W-14 (DWG 72KB) - Hydrant Installation for Limited Space with Standard Mechanical Joint Fittings
W-15 (DWG 83KB) - Hydrant Sump
W-16 (DWG 19KB) - Water System Valve Box Cover
W-17 (DWG 28KB) - Water System Valve Box
W-18 (DWG 43KB) - Valve & Box for Unpaved Locations
W-19 (DWG 28KB) - Water Valve Jacket Adjusted
W-20 (DWG 26KB) - Water Valve Jacket Lowered for Milling
W-21 (DWG 81KB) - Pipe Hanger Detail - Pending Structural Approval
W-22 (DWG 37KB) - Pipe Saddle Assembly for Water Main
W-23 (DWG 24KB) - Pipe Saddle Assemb1y for Water Main
W-24 (DWG 54KB) - 1" Air Release Valve
W-25 (DWG 25KB) - 1/2" Temporary Sample Tap
W-26 (DWG 31KB) - 2" Temporary Sample Tap for Stub Out
W-27 (DWG 20KB) - Flushing Valve Above Grade
W-28 (DWG 55KB) - Below Grade Flushing Hydrant
W-29 (DWG 35KB) - Pitometer Gauging Point
W-30 (DWG 43KB) - Typical Casing Detail
W-31 (DWG 62KB) - Mechanical Restraint Devices
W-32 (DWG 96KB) - Method or Adjustment over Existing Utilities using Mechanlica1 Restraint Devices
W-33 (DWG 102KB) - Method of Adjustment over Existing Utilities using Tie Rods
W-34 (DWG 98KB) - Method of Adjustment under Existing Utilities using Mechanical Restraint Devices
W-35 (DWG 103KB) - Method of Adjustment under Existing Utilities using Tie Rods
W-36 (DWG 36KB) - Plugged Dead End - Using Tie rods
W-37 (DWG 36KB) - Plugged Dead End - Using Mechanica1 Restraints
W-38 (DWG 115KB) - Thrust Block Size Chart
W-39 (DWG 64KB) - Temporary Sample Tap in Below Grade Flushing Valve
top
--- SANITARY SEWER STANDARD SECTION ---
S-1 (DWG 110KB) - Sanitary Sewer Manhole Cover and Frame
S-2 (DWG 107KB) - Sanitary Sewer Type "A" Manhole-Section View
S-3 (DWG 44KB) - Sanitary Sewer Type "A" Manhole-Plan View
S-4 (DWG 117KB) - Sanitary Sewer Type "B" Manhole-Section View
S-5 (DWG 40KB) - Sanitary Sewer Type "B" Manhole-Plan View
S-6 (DWG 57KB) - Sanitary Sewer Type "C" Manhole-Section View
S-7 (DWG 112KB) - Sanitary Sewer Type "D" Manhole-Section View
S-8 (DWG 42KB) - Sanitary Sewer Type "D" Manhole-Plan View
S-9 (DWG 96KB) - Sanitary Sewer Type "E" Manhole-Section View
S-10 (DWG 144KB) - Sanitary Sewer Type "F" Manhole-Section View
S-11 (DWG 113KB) - Sanitary Sewer Type "G" Manhole-Section View
S-12 (DWG 184KB) - Sanitary Sewer Type "H" Manhole-Section View
S-13 (DWG 106KB) - Sanitary Sewer Type "I" Manhole-Section View
S-14 (DWG 85KB) - Fiberglass Manhole
S-15 (DWG 66KB) - Manhole Pipe Connection & Alternate Manhole Bottom
S-16 (DWG 88KB) - Alternate Precast Base for Type A, B & C Manholes
S-17 (DWG 18KB) - Precast Joint Detail
S-18 (DWG 57KB) - Typical Force Main Connection to Manhole
S-19 (DWG 23KB) - House Lateral Plan A-A
S-20 (DWG 49KB) - House Lateral Section A-A
S-21 (DWG 22KB) - House Lateral Plan B-B
S-22 (DWG 56KB) - House Lateral Section B-B
S-23 (DWG 25KB) - 6" PVC House Connection-Over Conflict
S-24 (DWG 25KB) - 6" PVC House Connection-Under Conflict
S-25 (DWG 43KB) - Typical Casing Detail
S-26 (DWG 31KB) - Bedding Details-Class A
S-27 (DWG 26KB) - Bedding Details-Class B
S-28 (DWG 107KB) - Combination Air/Vacuum Release Valve Assembly in Manhole
S-29 (DWG 68KB) - Air Release Valve Assembly in Manhole
S-30 (DWG 45KB) - Valve and Box for Unpaved Locations
S-31 (DWG 17KB) - Sewer System Valve Box and Cover
S-32 (DWG 28KB) - Sewer System Valve Box
S-33 (DWG 27KB) - Sewer Valve Jacket Adjusted
S-34 (DWG 26KB) - Sewer Valve Jacket Lowered for Milling
S-35 (DWG 81KB) - Pipe Hanger Detail-Pending Structural Approval
S-36 (DWG 37KB) - Pipe Saddle Assembly for Sewer Main
S-37 (DWG 24KB) - Pipe Saddle Assembly for Sewer Main
S-38 (DWG 62KB) - Mechanical Restraint Devices
S-39 (DWG 96KB) - Method of Adjustment over Existing Utilities using Mechanical Restraint Devices
S-40 (DWG 102KB) - Method of Adjustment over Existing Utilities using Tie Rods
S-41 (DWG 98KB) - Method of Adjustment under Existing Utilities using Mechanical Restraint Devices
S-42 (DWG 103KB) - Method of Adjustment under Existing Utilities using Tie Rods
S-43 (DWG 36KB) - Plugged Dead End-Using Tie rods
S-44 (DWG 36KB) - Plugged Dead End-Using Mechanical Restraints
S-45 (DWG 115KB) - Thrust Block Size Chart
S-46 (DWG 189KB) - Private Pump Out Detail Assembly
top
--- TRAFFIC STANDARD SECTION ---
T-1 (DWG 33KB) - Intersection Loop Installation Plan View
T-2 (DWG 29KB) - Loop Detail
T-3 (DWG 76KB) - Wire Splice Detail
You will need AutoCAD or a similar product to open DWG files. AutoCAD is available at the Autodesk Company Web site: http://usa.autodesk.com/.
top
details.jaxdev.info